Home » Flow Meter » Electromagnetic Flow Meter » Can intelligent electromagnetic flowmeters measure mixtures?

Can intelligent electromagnetic flowmeters measure mixtures?

Intelligent electromagnetic flowmeter measurement accuracy is high, stable performance, is a very common product in the flow meter, widely used in petroleum, chemical, food and other industries, especially water resources system, almost everywhere can see the figure of intelligent electromagnetic flowmeter, but the measured medium in these occasions is a single liquid, then with intelligent electromagnetic flowmeter can measure the mixture, Is a lot of owners are very want to know, I hope that today through this article to answer everyone’s doubts.

Rated 4.9/5 based on 600 customer reviews
Share:
Content

1. Liquid containing bubbles

The liquid mixed with tiny bubbles can still be measured normally, but the mixed volume flow rate containing the volume of bubbles is measured. If the gas content increases to form a blocky flow, the electrode may be covered by the gas so that the circuit is disconnected instantaneously, and the output wobble or even cannot work normally.

2, solid-liquid two-phase flow of liquid

The volume flow of the two phases can also be measured for the solid-liquid two-phase fluid containing non-ferromagnetic particles or fibers. Fluids with high solid content, such as drilling mud, drilling cement mud, pulp, etc. Because the solid flows together in the carrier liquid, there is a slip between the two, the speed is different, single-phase liquid inspection instrument used for solid-liquid two-phase flow will produce additional errors.

There are large particles in the slurry across the electrode surface, in the low frequency rectangular excitation electromagnetic flowmeter will produce a peak slurry noise, so that the flow signal is unstable, it is necessary to choose a higher frequency instrument or a strong ability to suppress the slurry noise instrument.

3. Liquids containing ferromagnetic substances

The fluid containing ferromagnetic substances on the usual electromagnetic flowmeter, because the permeability of the measurement tube is changed by the different content of the ferromagnet, will produce measurement error, but in the magnetic circuit with a magnetic flux detection coil compensation electromagnetic flowmeter EMF, can reduce the influence of mixed with the ferromagnet. The test report shows that the water contains liquid solid weight ratio of about 4:1, granularity ≤0.15mm iron fine ore pulp, 80mm diameter instrument for water and slurry comparison flow test, the usual instrument indicates the value change of 7%-10%, equipped with magnetic flux detection coil instrument, indicating the value error within ±2%Fs.

4. Pulp

The pulp used to measure the ore particles should pay attention to the wear degree of the sensor lining, and the increase of the inner diameter of the measuring tube will cause additional errors. In this case, the ceramic lining or polyurethane rubber lining with better wear resistance should be used, and it is recommended that the sensor be installed on the vertical pipe to make the pipe wear uniform and eliminate the shortcomings of the local wear of the lower part of the horizontal installation.

In summary, the intelligent electromagnetic flowmeter can be used to measure the mixture, as long as the relevant adverse factors are avoided, the same can obtain good measurement results.

Inquiry


    More Electromagnetic Flow Meter

    Electromagnetic flowmeter is a speed meter to measure the volume flow of conductive media. While carrying out on-site monitoring and display, it can output standard current signals for recording, adjustment and control, realizing automatic control of detection, and realizing long-distance transmission of signals. It can be widely used in water, chemical, coal, environmental protection, textile, metallurgy, paper and other industries in the flow measurement of conductive liquid. The structure of the instrument has one type and one type.

    Performance Technical parameter
    Size DN3-DN3000mm
    Nominal Pressure 0.6-1.6Mpa(2.5Mpa/4.0Mpa/6.4Mpa…Max 42Mpa)
    Accuracy +/-0.5%(Standard)     +/-0.3% or +/-0.2%(Optional)
    Liner PTFE, Neoprene, Hard Rubber, EPDM, FEP, Polyurethane, PFA
    Electrode SUS316L, Hastelloy B, Hastelloy C       Titanium, Tantalum, Platinium-iridium
    Structure Type Integral type, remote type, submersible type, ex-proof type
    Medium Temperature -20~+60 degC(Integral type)
    Remote type ( Neoprene ,Hard Rubber ,Polyurethane ,EPDM) -10~+80degC
    Remote type(PTFE/PFA/FEP) -10~+160degC
    Ambient Temperature -20~+60deg C
    Ambient Humidity 5-100%RH(relative humidity)
    Measuring Range Max 15m/s
    Conductivity >5us/cm
    Protection Class IP65(Standard); IP68(Optional for remote type)
    Process Connection Flange (Standard), Wafer, Thread, Tri-clamp etc (Optional)
    Output Signal 4-20mA/Pulse
    Communication RS485(Standard), HART(Optional),GPRS/GSM (Optional)
    Power Supply AC220V (can be used for AC85-250V)
    DC24V (can be used for DC20-36V)
    DC12V (optional), Battery Powered 3.6V (optional)
    Power Consumption <20W Alarm Upper Limit Alarm / Lower Limit Alarm Self-diagnosis Empty Pipe Alarm, Exciting Alarm Explosion Proof ATEX