Home » Flow Meter » Electromagnetic Flow Meter » Electromagnetic flow meter several typical installation errors

Electromagnetic flow meter several typical installation errors

We have introduced a lot of relevant information about electromagnetic flowmeters before, and today we mainly introduce several typical installation errors to help you avoid these problems.

Rated 4.7/5 based on 391 customer reviews
Share:
Content

Several typical installation errors of electromagnetic flowmeters:

1, the flow measurement value fluctuates greatly

Question: Have you ever encountered a situation where the measurement results keep bouncing and cannot be stabilized?

Analysis: Most of the reasons for this situation are because there is a pump next to the flow meter at the installation site. When the medium passes through the flow, it is in a turbulent state, and the pump will interfere with the flow meter measurement, resulting in unstable measurement results.

Solution: Install the flow meter in an environment away from interference factors such as pumps, and ensure the length of the straight pipe section to ensure fluid stability.

2, the measurement value is inaccurate

Problem: The measurement results are not accurate, and sometimes there will be air traffic control alarm and lower limit alarm.

Analysis: The medium is not satisfied with the tube. If the flow meter wants to measure accurately, it must ensure that the medium is full.

Solution: Work process change to ensure that the medium is full tube.

3, the flow meter is damaged

Problem: The flow meter is flooded and damaged.

Analysis: The flowmeter is in the situation of long-term immersion, and the protection level is not suitable.

Solution: In the installation of the flow meter in long-term immersion water, we must choose the protection level of IP68, otherwise the electromagnetic flow meter will really break.

Aister instrument for you to introduce these three more typical installation problems, I believe there are some other problems in the field, if you encounter other problems that can not be solved about the electromagnetic flowmeter, you can contact Aister instrument at any time, we are ready to answer for you.

Inquiry


    More Electromagnetic Flow Meter

    Electromagnetic flowmeter is a speed meter to measure the volume flow of conductive media. While carrying out on-site monitoring and display, it can output standard current signals for recording, adjustment and control, realizing automatic control of detection, and realizing long-distance transmission of signals. It can be widely used in water, chemical, coal, environmental protection, textile, metallurgy, paper and other industries in the flow measurement of conductive liquid. The structure of the instrument has one type and one type.

    Performance Technical parameter
    Size DN3-DN3000mm
    Nominal Pressure 0.6-1.6Mpa(2.5Mpa/4.0Mpa/6.4Mpa…Max 42Mpa)
    Accuracy +/-0.5%(Standard)     +/-0.3% or +/-0.2%(Optional)
    Liner PTFE, Neoprene, Hard Rubber, EPDM, FEP, Polyurethane, PFA
    Electrode SUS316L, Hastelloy B, Hastelloy C       Titanium, Tantalum, Platinium-iridium
    Structure Type Integral type, remote type, submersible type, ex-proof type
    Medium Temperature -20~+60 degC(Integral type)
    Remote type ( Neoprene ,Hard Rubber ,Polyurethane ,EPDM) -10~+80degC
    Remote type(PTFE/PFA/FEP) -10~+160degC
    Ambient Temperature -20~+60deg C
    Ambient Humidity 5-100%RH(relative humidity)
    Measuring Range Max 15m/s
    Conductivity >5us/cm
    Protection Class IP65(Standard); IP68(Optional for remote type)
    Process Connection Flange (Standard), Wafer, Thread, Tri-clamp etc (Optional)
    Output Signal 4-20mA/Pulse
    Communication RS485(Standard), HART(Optional),GPRS/GSM (Optional)
    Power Supply AC220V (can be used for AC85-250V)
    DC24V (can be used for DC20-36V)
    DC12V (optional), Battery Powered 3.6V (optional)
    Power Consumption <20W Alarm Upper Limit Alarm / Lower Limit Alarm Self-diagnosis Empty Pipe Alarm, Exciting Alarm Explosion Proof ATEX